Flow scheme customization features in TDG

Flow scheme diversions were recently added to the Transcend Design Generator. Advanced users of the design generator know that the platform models wastewater treatment plants in the following structure (being substantially simplified here for the sake of explanation):

In some situations, however, it might be desirable to add certain “shortcuts” to this layout, e.g., in case of evaluating extreme hydraulic events, like stormwater influent; or it is possible that we are just curious how the design would change in case the flow is substantially reduced on the biology.

Enter flow scheme diversion

To address these use cases, TDG recently received some new features that enable the configuration of flow scheme diversions. If you check out the `Data/Flow` screen and open the `Advanced` section, the currently supported flow diversion options become available:

The three options can be illustrated by the following plant schemes:

Bypassing Primary to Disinfection

Bypass – from upstream Primary to Disinfection: this option can be used for classic stormwater treatment scenarios:

Here we enabled bypassing Primary to Disinfection, set the type of the bypass to `Overflow`, and adjusted the `Volumetric flow` field to 4000 m3/h.

This results in a behavior that the system diverts all flows above that value to the bypass branch, i.e., it behaves as if an overflow weir had been installed at the flow diversion point.

Bypassing Primary to Biology

For some of our users, it is a frequently occurring situation, that the primary filter installed at the treatment plant has limited capacity (or they investigate alternative designs with a limited primary filter capacity to reduce the load on the biology without covering the full capacity with primary filters), and needs to be protected from flows above a certain limit. For those cases bypassing Primary to Biology is an excellent solution.

Bypassing Biology to Disinfection

There are two frequently occurring use cases for this option:

1. We want to protect the biology from hydraulic peaks

2. We want to divert a certain fixed flow for e.g., seeding an auxiliary treatment train

For option #1 the configuration is similar to a full bypass demonstrated in section Bypassing Primary to Disinfection.

For option #2 the bypass needs to be configured as `Pumped`, just as the figure below demonstrates:

When a bypass type is set as `Pumped` then the system makes sure that the flow in that direction is always the configured value. The `Overflow` and `Pumped` concepts can be illustrated the best by the figures below:

What’s next?

In a later post we are going to share how you can configure the Design Generator if you want to reduce the scope of the designs for the water line only.

Want more?

Vote in the comments for the next hydraulic enhancements in the TDG!

Shall we implement:

– additional influent points?

– or more bypass options?

– or elevation data evaluation for existing sites and reactors/buildings?

– or something completely different?

Let us know your preference!

Clients

Technology Providers & OEMs Technology Providers & OEMs

TDG rapidly generates accurate budgetary proposals to help suppliers bid more, win more, and sell more.

Asset Owners and Utilities Asset Owners and Utilities

TDG streamlines the capital planning and conceptual design processes to accelerate project timelines and deliver better outcomes.

EPCs, AECs, and Consultants EPCs, AECs, and Consultants

TDG enables engineering firms to deliver more value to their clients & increase competitiveness.

Individuals Individuals

TDG works for individual engineers who want to grow their business and reduce their non-billable time.

Academic Academic

Transcend supports students and professors around the world to incorporate TDG into their curriculum.

Resources

Articles Articles

Read posts written by Transcend team members sharing their points of view on the company mission, vision, and products.

Webinars Webinars

Register for our upcoming webinars or watch on-demand webinars like Transcend’s popular ‘How To’ Series.

Case studies Case studies

Understand how Transcend’s customers are utilizing TDG to bring more value to their customers and grow their businesses.

FAQ FAQ

View a list of the questions we are most frequently asked about our company and our software

Transcend tools Transcend tools

Access a number of tools Transcend has developed to help engineers and industry professionals take back their time.

Security Security

Learn more about Transcend’s security practices

Industries

Water and Wastewater Water and Wastewater

TDG creates unique, optimized designs of water & wastewater treatment facilities by automatically combining decisions and calculations from each engineering field.

Power Power

TDG creates unique, optimized designs of T&D assets by automatically combining decisions and calculations from each engineering discipline.

Solutions

WWTP Design WWTP Design

TDG generates optimized, unique designs for water and wastewater treatment facilities by automating decisions and calculations across engineering fields.

Substation Design Substation Design

TDG generates optimized, unique designs for T&D assets by automating decisions and calculations across engineering disciplines.

Utility Interconnection Hub Utility Interconnection Hub

For transmission providers and power utilities, simplify the interconnection process by integrating TDG into your website to ensure developers submit fully compliant collector substation designs from the start.

Transcend Proposal Generator Transcend Proposal Generator

Enables technology suppliers and OEMs to generate more proposals, faster, with more detail and less resources, so you can sell more of your technology and/or equipment

White Label Proposal Generator White Label Proposal Generator

Generate qualified leads, elevate your customer experience, and simplify your engineering and channel partner workflows in an intuitive, user-friendly interface integrated into your website.

PFAS Feasibility Study PFAS Feasibility Study

For drinking water utilities, automatically generate accurate CAPEX and OPEX estimates to calculate the cost of upgrading your facility to meet stringent PFAS regulations

Booster Station Design Booster Station Design

Automates and simplify the complex process of designing booster pumping stations

DC Battery Sizing DC Battery Sizing

Get precise battery sizing recommendations in minutes for renewable energy and other critical infrastructure projects